TALOS C730
Automatic bollard for perimeter security
Automatic oil-hydraulic system, 230 Vac
PERIMETER SECURITY
Intended for traffic control and protection of those sensitive areas (military stations, police headquarters, airports, etc.), where a high level of perimeter security is needed against terrorist attacks. Designed and tested to withstand, in a single bollard configuration, A 16,500 lb vehicle traveling at 30 mph.
OIL-HYDRAULIC
Hydraulic locking device in standing position (standard) and emergency manual lowering by a release spanner supplied with the equipment. Burglar-proof cover plate preventing the release system from being accessed and thus the bollard from being lowered.
STRONG
Scratch-proof cataphoresis treated and polyester powder coated steel rising cylinder. Available also with an AISI 304 stainless steel cover sleeve, thickness 12/10. Breakout resistance: 750,000 J.
Connector and junction box IP 66 for cabling. Hall effect limit switch sensors, cylinder head with rubber edge and incorporated LED lights.
VERSATILE
A vast range of command and safety accessories allow for reliable and precise control of the installations. Beeper to signal the movements. Heating device for installations in very low temperature conditions (-40 °F) where snow and ice are frequent. The electronic control unit can be set so that it can manage several bollards at a time.
CERTIFICATES
Classes of performance: K4 / M30 / C730
Certified: ASTM F2656-18A C730
PAS 68:2013 V/7500 (N3)/48
IWA 14-1:2013 V/7200 [N3C]/48

Cylinder diameter (inches) 10.83
​​
Cylinder thickness (inches) 0.47
​
Cylinder height from ground (inches) 39.37
​
Cylinder material: S355J2H steel
​
Cylinder treatment and finishing: cataphoresis and polyester powder coating RAL 7016AISI 304 brushed SS steel sleeve
​
Pit: hot dip galvanization
​
Rising time (s) [cm/s] ~5,00 [20]
​
Lowering time (s) [cm/s] ~4,20[23]
​
Working temperature (°F) -4 / 176 -40 [A]
​
Oil type: 187 gallons
​
Power supply (Vac – Hz) 230 - 50
​
Absorbed power (W) 1.850
​
Absorbed current (A) 5
​
Grade of protection P / motor-pump: 67
​
Frequency of use (cycles/day): heavy duty / 2,000
​
Impact resistance (J) 250,000
​
Breakout resistance (J) 750,000
​
Maximum static load (lbs) 44
​